The following analyses can be done in our laboratory:
| Analysis | Test |
|---|---|
| Kinematic Viscosity – Stabinger | EN 16896 |
| Kinematic Viscosity – Ubbelohde | DIN 51 562 |
| Dynamic viscosity with ball drop according to Höppler | DIN 53 015 |
| Viscosity cup (similar to Ford Cup) | DIN 53 211 |
| Cone Penetration | ISO 2137 |
| Flashpoint Cleveland open cup | ISO 2592 |
| Flashpoint Pensky-Martens – closed cup | DIN EN 22 719 |
| ASTM D 1500 Colour with Lovibond | ISO 2049 |
| Gardner Colour with Lovibond | Gardner |
| Gardner Density | DIN 51 757 |
| Neutralisation No. | DIN 51 558 |
| Infrared spectrometric analysis | DIN 51 451 |
| pH-value of water soluble coolants | DIN 51 369 |
| Corroision protection properties of water soluble coolants | DIN 51 360 |
| Photometric determination of coolants concentratrion | (Refraktometer) |
| Bacteria, yeast and fungal attack of coolants | Teströ-Test |
| Foaming behaviour of coolants | In-house test |
| Creaming of emulsions | In-house test |
| Emulsification behaviour of emulsions | In-house test |
| Sedimentaion (Centrifuge) | In-house test |
| Friction wear by Reichert | In-house test |
| coating capacity on hot surfaces | In-house test |
| X-ray fluorescence analysis | In-house test |
| Analysis [Test] |
|---|
| Kinematic Viscosity – Stabinger [EN 16896] |
| Kinematic Viscosity – Ubbelohde [DIN 51 562] |
| Dynamic viscosity with ball drop according to Höppler [DIN 53 015] |
| Viscosity cup (similar to Ford Cup) [DIN 53 211] |
| Cone Penetration [ISO 2137] |
| Flashpoint Cleveland open cup [ISO 2592] |
| Flashpoint Pensky-Martens – closed cup [DIN EN 22 719] |
| ASTM D 1500 Colour with Lovibond [ISO 2049] |
| Gardner Colour with Lovibond [Gardner] |
| Gardner Density [DIN 51 757] |
| Neutralisation No. [DIN 51 558] |
| Infrared spectrometric analysis [DIN 51 451] |
| pH-value of water soluble coolants [DIN 51 369] |
| Corroision protection properties of water soluble coolants [DIN 51 360] |
| Photometric determination of coolants concentratrion [Refraktometer] |
| Bakteria, yeast and fungal attack of coolants [Teströ-Test] |
| Foaming behaviour of coolants [S&M Haustest] |
| Creaming of emulsions [S&M Haustest] |
| Emulsification behaviour of emulsions [S&M Haustest] |
| Sedimentaion (Centrifuge) [S&M Haustest] |
| Friction wear by Reichert [S&M Haustest] |
| coating capacity on hot surfaces [S&M Haustest] |
| X-ray fluorescence analysis (RFA) [S&M Haustest] |
Further analyses are also possible.